home *** CD-ROM | disk | FTP | other *** search
/ Night Owl 6 / Night Owl's Shareware - PDSI-006 - Night Owl Corp (1990).iso / 001a / usrinfo.zip / CR2400E.INF < prev    next >
Text File  |  1991-10-08  |  26KB  |  560 lines

  1.  
  2.  
  3.  
  4.  
  5.  
  6.  
  7.  
  8.  
  9.  
  10.     __   __ _   ________         ___
  11.    |  | |  |     HHHHHHH         HHH
  12.    |  | |  |  |  HHH HHH         HHH                   sss
  13.    |  | |  |  |  HHH HHH  sssss  HHHsss   sssss   HHH  """  sssss   sssss
  14.    |  | |  |  |__HHH_HHH HHH HHH HHH HHH HHH HHH HHHHH HHH HHH HHH HHH HHH
  15.    |  | |  |\_  \HHHHHH" HHH HHH HHH HHH HHH HHH  HHH  HHH HHH HHH HHH HHH
  16.    |  | |  |  |  HHH HHH HHH HHH HHH HHH HHH HHH  HHH  HHH HHH     "HHsss
  17.    |  | |  |  |  HHH HHH HHH HHH HHH HHH HHH HHH  HHH  HHH HHH HHH sss HHH
  18.    |  `-'  |  |  HHH HHH HHH HHH HHH HHH HHH HHH  HHH  HHH HHH HHH HHH HHH
  19.     -------      """ """  """""" """"""   """""   """  """  """""   """""
  20.  
  21.  
  22.  
  23.      HHHHHH    HHHHHH   HH    HH  HHHHHHHH    HHHHHHHH  HHHHHHHH  HHHHHHHH
  24.     HHHHHHHH  HHHHHHHH  HH    HH  HHHHHHHHH      HH     HHHHHHHH  HHHHHHHHH
  25.     HH     H  HH    HH  HH    HH  HH     HH      HH     HH        HH     HH
  26.     HH        HH    HH  HH    HH  HHHHHHHHH      HH     HH        HHHHHHHHH
  27.     HH        HH    HH  HH    HH  HHHHHHH        HH     HHHHHH    HHHHHHH
  28.     HH        HH    HH  HH    HH  HH   HHH       HH     HH        HH   HHH
  29.     HH     H  HH    HH  HH    HH  HH    HHH      HH     HH        HH    HHH
  30.     HHHHHHHH  HHHHHHHH  HHHHHHHH  HH     HH      HH     HHHHHHHH  HH     HH
  31.      HHHHHH    HHHHHH    HHHHHH   HH     HHH  HHHHHHHH  HHHHHHHH  HH     HHH
  32.  
  33.           HHHHHHH          HH    HHHHHHHH    HHHHHHHH
  34.          HH    HHH       HHHH   HHHHHHHHHH  HHHHHHHHHH
  35.          HH    HHH      HH HH   HHH    HHH  HHH    HHH   HHHHHHHHH
  36.               HHH      HH  HH   HHH    HHH  HHH    HHH  HH       HH
  37.             HHH       HH   HH   HHH    HHH  HHH    HHH  HH       HH
  38.            HHH       HH    HHH  HHH    HHH  HHH    HHH  HHHHHHHHHH
  39.          HHH        HHHHHHHHHH  HHH    HHH  HHH    HHH  HH
  40.         HHHH    HHH       HHH   HHHHHHHHHH  HHHHHHHHHH  HH       HH
  41.         HHHHHHHHHHH      HHHHH   HHHHHHHH    HHHHHHHH    HHHHHHHHH
  42.  
  43.  
  44.  
  45.      The USRobotics Courier 2400e modem is the new choice for today's
  46. sophisticated data communicators who demand the highest standards of quality
  47. and reliability from their equipment.  The $349.00 Courier 1200 offers a
  48. combination of price, performance, quality, and reliability that other
  49. 1200/300 bps modems can't match.
  50.  
  51.      The Courier 2400e is a fully-featured modem that with special features
  52. that professional users will find ingenious and indispensable.  Standard
  53. features found on the Courier 2400e include:
  54.  
  55.      *  MNP ERROR CONTROL:  The Courier 2400e implements MNP, a sophisticated
  56. error and data flow control protocol that ensures error-free data transfer.
  57. The protocol is especially useful when files containing numeric data are being
  58. transferred, or computer programs, in which a single incorrect character can
  59. cause failure.
  60.  
  61.      *  INACTIVITY TIMER:  You can set the modem to automatically hang up
  62. after a specified number of minutes if there is no activity on the phone line.
  63.  
  64.      *  DATA RATE CONVERSION:  You can set your computer's serial port to
  65. operate at a specific data rate (say 19,200 bps) and the modem will perform a
  66. data rate conversion for whatever speed modem you call.  That means no more
  67. software problems with automatic baud rate detection.
  68.  
  69.      *  BOTTOM PANEL REFERENCE: On the bottom of the Courier case, you'll find
  70. a command summary and other handy reference information, as well as the bank
  71. of Dual In-Line Package (DIP) switches used to tailor operations to your
  72. requirements.
  73.  
  74.      *  CALL DURATION REPORTING:  The Courier 2400e records the duration of
  75. your calls in hours, minutes, and seconds.  This feature enables you to
  76. display and print an audit of your calling activities.  You can optionally use
  77. the modem clock as a real-time clock.
  78.  
  79.      *  CALL PROGRESS DETECTION:  The Courier 2400e has additional call-
  80. progress result codes (screen messages) that let you know when a line is busy,
  81. a person rather than a modem has answered the phone, there is no dial tone, or
  82. the distant phone is ringing.
  83.  
  84.      *  MODEM SETTINGS DISPLAY:  On command, the modem sends a display of its
  85. current settings, a handy way to check your transmission rate, S-registers,
  86. and other operational controls.
  87.  
  88.      *  HELP SCREENS:  You can also display screens that summarize the command
  89. set, S-register functions, and Dial command options.
  90.  
  91.      *  REPEAT COMMAND:  You can have the modem continuously repeat a command
  92. until instructed otherwise.  This is especially usefule in dialing services
  93. whose lines are often busy.
  94.  
  95.      *  QUOTE MODE:  You can put the modem in Quote Mode
  96.  
  97.      *  ADAPTIVE DIALING:  You can set the Courier 2400e so that it auto-
  98. matically uses touch-tone dialing.  If tone dialing doesn't work on the line,
  99. the modem automatically switches to the slower type, pulse (rotary).
  100.  
  101.      *  DATA RATE FALLBACK:  In addition to automatically adjusting to the bit
  102. rate of incoming calls (0-300, 1200, 2400 bits per second, or bps), the
  103. Courier 2400e incorporates the V.22bis fallback recommendation when dialing.
  104. If the called modem operates at 1200 bps, the Courier 2400e automatically
  105. drops
  106. back to 1200 bps.
  107.  
  108.      *  AUTOMATIC RETRAINING:  The Courier 2400e observes the V.22bis retrain
  109. sequence, which enables modems communicating at 2400 bps to compensate for
  110. certain problems that may affect data reliability.
  111.  
  112. _____________________________________________________________________________
  113.  
  114.                               STANDARDS COMPLIANCE
  115. ______________________________________________________________________________
  116.  
  117.  
  118. Bell 103/113 at 300 bps                       Bell 212A at 1200 bps
  119.  
  120. CCITT V.22bis at 2400 bps                     Ringer Equivalence: 0.4B
  121.  
  122. FCC Part 15#:  CJE794COURIER24E                  Canadian DOC LN#: 33B
  123.  
  124. FCC Part 68#: CJE794-11323-DM-E
  125.  
  126. ______________________________________________________________________________
  127.  
  128.                              AT COMMANDS SUPPORTED
  129. ______________________________________________________________________________
  130.  
  131.   COMMAND    DEFAULT         FUNCTION
  132.  
  133.     &          DNA           See the Extended Command Summary that follows
  134.                              this basic set
  135.  
  136.     A          DNA           Forces Answer Mode
  137.  
  138.     A/         DNA           Reexecute last command (does not require "AT" or
  139.                              <CR>
  140.  
  141.   Any Key      DNA            Terminate current dialing operation resulting
  142.                              from issued dial command
  143.  
  144.     AT         DNA           Attention.  MUST precede all commands except A/
  145.                              and +++.
  146.  
  147.     Cn         C1            Set additional modem to Receive-Only
  148.                              C0   Transmitter disabled
  149.                              C1   Transmitter enabled
  150.  
  151.     D         Pulse          Dial the number that follows and enter
  152.               Dial          originate mode; use with any of these options:
  153.                              S   Dial the number stored in NRAM
  154.                              P   Pulse (rotary) dial (0-9) -- DEFAULT
  155.                              T   Touch-tone dial (0-9, #, *)
  156.                              ,   (Comma)  Pause two seconds, then continue
  157.                              ;   (Semi-colon) Return to command mode after
  158.                                  dialing
  159.                              R   Reverse Originate and Answer Frequencies
  160.                              "   Dial the letters that follow
  161.                              !   Transfer call (flash the switchhook)
  162.                              W   Wait for second dial tone (with X3 or higher)
  163.                              @   Wait for answer (with X3 or higher)
  164.  
  165.     E          E0            Command mode local echo ON/OFF
  166.                              E0  Echo OFF
  167.                              E1  Echo ON
  168.  
  169.     F          F1            Online local echo ON/OFF
  170.                              F0   Echo ON
  171.                              F1   Echo OFF
  172.  
  173.     Hn         H0             ON/OFF hook control
  174.                              H0   Hang up (go on hook)
  175.                              H1   Go off hook
  176.  
  177.     In        DNA            Inquiry
  178.                              I0   Display product code
  179.                              I1   Display memory (ROM) checksum
  180.                              I2   Run Memory (RAM) test
  181.                              I3   Return call duration or real time (see Kn)
  182.                              I4   Return current modem settings
  183.  
  184.     Kn        K0             Modem clock operation :  call duration or real
  185.                              time
  186.                              K0   Return call duration at ATI3
  187.                              K1   Return actual time at ATI#.  Clock is set
  188.                              using ATI3=HH:MM:SS K1
  189.  
  190.     Mn        M1             Audio Monitor (speaker) control
  191.                              M0   Speaker always OFF
  192.                              M1   Speaker ON until "CONNECT"
  193.                              M2   Speaker always ON
  194.                              M3   Speaker ON after last digit dialed and until
  195.                              carrier is established.
  196.  
  197.     O         DNA            Toggle back online after command execution
  198.  
  199.     P         Pulse          Pulse (rotary) Dial
  200.  
  201.     Qn        Q0             Enable/Suppress result codes
  202.                              Q0   Result codes displayed
  203.                              Q1   Result Codes suppressed
  204.  
  205.    Sr=n       DNA            Sets S-Register r to value n where n is a decimal
  206.                              number from 0 to 255
  207.  
  208.    Sr?        DNA            Query value of register r
  209.  
  210.     T        Pulse           Touch-tone dial
  211.  
  212.     Vn        V1             Verbal/numeric result codes
  213.                              V0   Numeric result codes
  214.                              V1   Verbal result codes
  215.  
  216.     Xn        X1             Result code set
  217.                              X0   Basic 0-4
  218.                              X1   Extended  0-5
  219.                              X2   Advanced (full) set plus fast dialing
  220.                              (immediately on dial-tone detect) and repeat
  221.                              dialing up to ten times
  222.  
  223.            RESULT CODES / SPECIAL DIALING FUNCTIONS OPTIONS TABLE
  224.  
  225.     RESULT CODES                       X0  X1  X2  X3  X4 │ X5 │ X6 |
  226.  
  227.     0/OK                                X   X   X   X   X   X   X
  228.     1/CONNECT                           X   X   X   X   X   X   X
  229.     2/RING                              X   X   X   X   X   X   X
  230.     3/NO CARRIER                        X   X   X   X   X   X   X
  231.     4/ERROR                             X   X   X   X   X   X   X
  232.     5/CONNECT 1200                          X   X   X   X   X   X
  233.     6/NO DIAL TONE                              X       X       X
  234.     7/BUSY                                          X   X   X   X
  235.     8/NO ANSWER (requires @,
  236.               replaces 3/NO CARRIER)                X   X   X   X
  237.     10/CONNECT 2400                         X   X   X   X   X   X
  238.     11/RINGING                                              X   X
  239.     12/VOICE                                                X   X
  240.  
  241.     SPECIAL DIALING FUNCTIONS
  242.     Adaptive Dialing                            X   X   X   X   X
  243.     Wait for 2nd Dial Tone (W)                      X   X   X   X
  244.     Wait for Answer                                 X   X   X   X
  245.     Fast Dial                                   X       X       X
  246.  
  247.  
  248.     Z         DNA            Reset modem to factory defaults.
  249.  
  250.    +++        DNA            Disconnect or return to command mode.  Must be
  251.                              preceded and followed by at least one second of
  252.                              no data entry/transmission; does not take AT or
  253.                              <CR>.
  254.  
  255.     >         DNA            Repeat command string until canceled by pressing
  256.                              any key.  If used in Dial String, automated
  257.                              redial terminates after ten attempts.
  258.  
  259.     $         DNA            Help command summary request.
  260.  
  261.    D$         DNA            Help Dial command summary request.
  262.  
  263.    S$         DNA            Help S-register summary request.
  264.  
  265.    &$         DNA            Help extended command summary request.
  266.  
  267. <Ctrl> C      DNA            Cancel display of Help screens.
  268.  
  269. <Ctrl> K      DNA            Cancel display of Help screens.
  270.  
  271. <Ctrl> S      DNA            Stop/restart display of Help screen.
  272.  
  273. ______________________________________________________________________________
  274.  
  275.                              EXTENDED COMMAND SET
  276. ______________________________________________________________________________
  277.  
  278.    &An       &A1             Enable/disable /ARQ result codes
  279.                              &A0  Suppress /ARQ result codes
  280.                              &A1  Display /ARQ result codes
  281.  
  282.    &Bn        &B0            Data rate, terminal to modem (DTE/DCE)
  283.                              &B0   Detect DTE rate from AT command (default)
  284.                              &B1   300 bps
  285.                              &B2   600 bps
  286.                              &B3   1200 bps
  287.                              &B4   2400 bps
  288.                              &B5   4800 bps
  289.                              &B6   9600 bps
  290.                              &B7   19200 bps
  291.  
  292.    &F         DNA            Load factory settings into RAM
  293.  
  294.    &Hn        &H0            Transmit Data flow control
  295.                              &H0  Flow control disabled
  296.                              &H1  Hardware (CTS, Pin 5) flow control
  297.                              &H2  software (XON/XOFF) flow control
  298.                              &H3  Hardware and software flow control
  299.  
  300.    &In        &I0            Received Data flow control
  301.                              &I0  Flow control disable
  302.                              &I1  XON/XOFF to local modem and remote system
  303.                              &I2  XON/XOFF to local modem only
  304.  
  305.    &Mn        &M4            Normal or Error Control Modes
  306.                              &M0  Normal Mode
  307.                              &M4  Normal/ARQ Mode -- normal if ARQ connection
  308.                                   cannot be made
  309.                              &M5  ARQ Mode -- hang up if ARQ connection cannot
  310.                                   be made
  311.  
  312.    &Nn        &N0            Data Rate, data link (DCE/DCE)
  313.                              &N0  Normal Link Operations
  314.                              &N1  300 bps
  315.                              &N2  1200 bps
  316.                              &N3  2400 bps
  317.  
  318.    &Rn        &R1            Received Data hardware (RTS, Pin 4) flow control
  319.                              &R0  Reserved for future use
  320.                              &R1  Ignore RTS default
  321.                              &R2  Received data output on RTS high; used only
  322.                                   if terminal equipment supports RTS (Pin 4)
  323.  
  324.    &Sn        &S0            Data Set Ready (DSR Pin 6) override
  325.                              &S0  DSR override (always ON)
  326.                              &S1  Modem controls DSR
  327.  
  328.    &W         DNA            Write current settings to nonvolatile random
  329.                              access memory (NRAM)
  330.  
  331.    &Y         &Y1            Break handling.  Destructive breaks clear the
  332.                              buffer; expedited Breaks are sent immediately to
  333.                              the remote system.
  334.                              &Y0  Destructive; don't send break
  335.                              &Y1  Destructive, expedited
  336.                              &Y2  Non-destructive, expedited
  337.                              &Y3  Non-destructive, unexpedited; modem sends
  338.                                   Break in sequence with data received from
  339.                                   terminal equipment
  340.  
  341.    &Z         DNA            Store the phone number that follows in NRAM
  342.  
  343.  
  344. ______________________________________________________________________________
  345.  
  346.                                 THE RESULT CODES
  347. ______________________________________________________________________________
  348.  
  349.     NUMERIC/VERBAL CODE                     MEANING
  350.  
  351.          0/OK                Command has been executed.
  352.  
  353.          1/CONNECT           Connection successfully made; if X1 or X2 is set,
  354.                              connection is at 300 bps.
  355.  
  356.          2/RING              Incoming call when modem set to Auto Answer.
  357.  
  358.          3/NO CARRIER        Hung up because attempt to connect failed or call
  359.                              was disconnected.
  360.  
  361.          4/ERROR             Invalid command.
  362.  
  363.          5/CONNECT 1200      Connection successfully made at 1200 bps.
  364.  
  365.          6/NO DIAL TONE      Hanging up; no dial tone.
  366.  
  367.          7/BUSY              Hanging up; busy signal.
  368.  
  369.          11/RINGING          Dialed and remote phone is ringing.
  370.  
  371.          12/VOICE            Hanging up; voice answered.
  372.  
  373. ______________________________________________________________________________
  374.  
  375.                               S-REGISTERS SUPPORTED
  376. ______________________________________________________________________________
  377.  
  378.  REGISTER  DEFAULT          FUNCTION
  379.  
  380.     S0       S0=0           Sets the number of rings on which to answer when
  381.            or DIP #5        in Auto Answer Mode
  382.  
  383.     S1       S1=0           Counts and stores the number of rings from
  384.  
  385.     S2       S2=43          Sets the ASCII decimal code for the escape code
  386.                             character.  Default character is "+".  A value of
  387.                             128-255 disables the escape code.
  388.  
  389.     S3       S3=13          Sets the ASCII decimal code for the Carriage
  390.                             Return character
  391.  
  392.     S4       S4=10          Sets the ASCII decimal code for the Line Feed
  393.                             character
  394.  
  395.     S5       S5=8           Sets the ASCII decimal code for the Backspace
  396.                             character.  A value of 128-255 disables the
  397.                             backspace key's delete function.
  398.  
  399.     S6       S6=2           Sets the number of seconds the modem waits before
  400.                             dialing.  If set below two, the modem resets S6 to
  401.                             2, due to phone company limitations.  If the modem
  402.                             is set to X2, the modem ignores S6 and dials as
  403.                             soon as it detects a dial tone (fast dial)
  404.  
  405.     S7       S7=30          Sets the number of seconds the modem waits for a
  406.                             carrier.  May be set for much longer duration if,
  407.                             for example, the modem is originating an
  408.                             international connection.
  409.  
  410.     S8       S8=2           Sets the duration , in seconds, for the pause (,)
  411.                             option in the Dial command
  412.  
  413.     S9       S9=6           Sets the required duration of the remote modem's
  414.                             carrier signal, in tenths of a second, before
  415.                             recognition (Carrier Detect Time)
  416.  
  417.     S10      S10=7          Sets the duration, in tenths of a second, the
  418.                             modem waits after loss of carrier before hanging
  419.                             up.  While we don't recommend use of call waiting
  420.                             on data lines, if you use call waiting you may
  421.                             want to set this register higher to prevent the
  422.                             modem from interpreting a signal for a second call
  423.                             as a disconnect from the remote modem.
  424.  
  425.  
  426.     S11     S11=70          Sets the duration and spacing, in milliseconds, of
  427.                             dialed Touch-Tones.
  428.  
  429.     S12     S12=50          Sets the duration, in fiftieths of a second, of
  430.                             the guard time for the escape code sequence.  Must
  431.                             be value between 1 and 255.
  432.  
  433.     S13                     Bit-mapped register.  By default, the bits are set
  434.                             to zero (off).  Select the bit(s) you want on, and
  435.                             set S13 to the total of the values in the "Value
  436.                             column.  For example, ATS13=20 enables bits 2
  437.                             (value = 4) and 4 (value = 16).
  438.  
  439.                             Bit  Value              Result
  440.  
  441.                              0     1    Reserved
  442.                              1     2    Reverse normal Auto Answer operations:
  443.                                         on incoming RING, enter Originate Mode
  444.                                         and look for Answer tone
  445.                              2     4    Disable 250 millisecond pause before
  446.                                         result code display
  447.                              3     8    Auto Dial:  When DTR goes from low to
  448.                                         high, automatically dial the number
  449.                                         stored in NRAM (execute DS)
  450.                              4    16    At power on or reset, automatically
  451.                                         dial the number stored in NRAM
  452.                                         (execute DS)
  453.                              5    32    Reserved
  454.                              6    64    Disable MNP Service Class 3 (used for
  455.                                         testing Service Class 2)
  456.                              7   128    Watchdog hardware reset, same as power
  457.                                         on (used in factory testing)
  458.  
  459.     S14      DNA            Returns product code
  460.  
  461.     S16     S16=0           Modem self-test. Set to 0 for Data Mode; set to 1
  462.                             for Analog Loopback Test
  463.                             S16 = 0   Data Mode (no testing)
  464.                                 = 1   Analog Loopback
  465.                                 = 2   Dial Test
  466.                                 = 4   Test Pattern
  467.                                 = 5   Analog Loopback with Test Pattern
  468.  
  469.     S17    S17=0            Received Link Disconnect Reason, MNP.
  470.  
  471.     S19    S19=0            Sets the number of minutes before the Inactivity
  472.                             Timer times out and the Courier hangs up
  473.  
  474.     S20     DNA             Stores the reason for the NO CARRIER result code:
  475.                              0  Key press abort
  476.                              1  DTR dropped
  477.                              2  Escape code (+++) issued
  478.                              3  Loss of carrier
  479.                              4  Inactivity timeout
  480.                              5  ARQ incompatibility (&M5 Mode)
  481.                              6  ARQ Retry timeout (Max. 12 tries)
  482.                              7  Received Link Disconnect
  483.  
  484. ______________________________________________________________________________
  485.  
  486.                            RS-232-C PIN DEFINITIONS
  487. ______________________________________________________________________________
  488.  
  489.               PIN                       FUNCTION
  490.  
  491.               1               Frame Ground (Common)
  492.               2               Transmit Data (Terminal to Modem)
  493.               3               Receive Data (Modem to Terminal)
  494.               5               Clear to Send (Modem to Terminal)
  495.               6               Data Set Ready (Modem to Terminal)
  496.               7               Signal Ground (Common)
  497.               8               Carrier Detect (Modem to Terminal)
  498.              12               Speed Indicate (Modem to Terminal)
  499.              20               Data Terminal Ready (Terminal to Modem)
  500.              22               Ring Indicate (Modem to Terminal)
  501.  
  502. ______________________________________________________________________________
  503.  
  504.                                   DIP SWITCHES
  505. ______________________________________________________________________________
  506.  
  507.               SWITCH                    FUNCTION
  508.  
  509.               1               DTR Override
  510.               2               Verbal/Numeric Result Codes
  511.               3               Display/Suppress Result Codes
  512.               4               Command Mode Local Echo
  513.               5               Auto Answer enable/disable
  514.               6               Carrier Detect Override
  515.               7               Single/multiple phone installation
  516.               8               "AT" command set recognition/Dumb mode
  517.               9               Escape Code (+++) Operations / 10/11 bits per
  518.                               character
  519.              10               Power-on Software defaults (customized NRAM vs.
  520.                               factory ROM settings)
  521.            Quad               Reverses pins 2 and 3 on RS-232-C connector
  522.  
  523. ______________________________________________________________________________
  524.  
  525.                          DIAGNOSTICS AND LED INDICATORS
  526. ______________________________________________________________________________
  527.  
  528.               LEDs            High Speed
  529.                               Auto Answer/Answer
  530.                               Carrier Detect
  531.                               Off Hook
  532.                               Receive Data
  533.                               Send Data
  534.                               Terminal Ready
  535.                               Modem Ready/Power/Analog Loopback
  536.                               Request to Send
  537.                               Clear to Send
  538.                               MNP Connection established
  539.  
  540.               Diagnostics     Analog Loopback Self-Test
  541.                               Test Pattern Generation
  542. _____________________________________________________________________________
  543.  
  544.  
  545.  
  546.  
  547.  
  548.  
  549.  
  550.  
  551.  
  552.  
  553.  
  554.  
  555.  
  556.  
  557.  
  558.  
  559.  
  560. ==============================================================================